Wagner
Aspirating Smoke Detection - Online Consultant Pack
Rev 1 - Jan 2025 | |||||||
General Information | |||||||
Basic Aspirating Fire Detection Information |
Wagner
Titanus Catalog Suppression Panel Design Excel |
Click to Install : Xpress Plus Design Software |
UL
Listing FM listing | ||||
Quick Budget Selection Excel Macros(WIP) |
Simplex
Total Solution for Data Center NFPAGuidelines |
PIpe Xpress + Video Pipe Xpress PPT |
|||||
A.
Microsens Standard and Room
IDENT
PROSENS Standard /Silent Standalone, Net or Net with Sensor
Variant.
Top Sens | |||||||
MICROSENS - STD |
MICROSENS - ROOM IDENT |
PROSENS - STD & SI |
PROSENS NET - STDSL TP3U |
PROSENS NET - STDSL TP4U |
PROSENS
NET - STDSL TP5U |
TOPSENS
STD SL | |
Small ASP Coverage |
Single Pipe for 5 Rooms |
Standalone
2 Detector Piping for SFD, EWSD, VEWSD |
With
Remote Terminal Monitoring with 2 Detector similar application |
With
Remote Terminal Monitoring with 2 Detector similar application |
With Remote Terminal Monitoring with 2 Detector similar application | With Remote Terminal Monitoring with 2 Detector similar
applicationc | |
1. Detector Module :01 set. | 1. Detector Module :01 set. | 1. Detector Module :02 set. | 1. Detector Module :02 set. | 1. Detector Module :02 set. | 1. Detector Module :02 set. | 1. Detector Module :02 set. | |
2. Coverage: 400 sqm @ Detector | 2.
Coverage: 400 sqm @ Detector |
2.
Coverage: 3Ksqm @ Detector |
2.
Coverage: 3K sqm @ Detector |
2.
Coverage: 3K sqm @ Detector |
2.
Coverage: 3K sqm @ Detector |
2.
Coverage: 3K sqm @ Detector | |
3. Max Pipelength: : 40-50m | 3. Max Pipelength: : 40-50m | 3. Max Pipelength: : 300m | 3. Max Pipelength: : 300m | 3. Max Pipelength: : 300m | 3. Max Pipelength: : 300m | 3. Max Pipelength: : 300m | |
4a. Max : 8 Holes | 4a. Max : 5 Holes | 4a. Std: 2 Det x 63 Holes | Std: 2 Det x 63 Holes | 4a. Std: 2 Det x 63 Holes | 4a. Std: 2 Det x 63 Holes | 4a. Std: 2 Det x 63 Holes | |
4b. Silent: 1 x 100/ 2 x 72 Holes |
4b. Silent: 1 x 100/ 2 x 72 Holes |
4b. Silent: 1 x 100/ 2 x 72 Holes |
4b. Silent: 1 x 100/ 2 x 72 Holes |
4b. Silent: 1 x 100/ 2 x 72 Holes | |||
5. Ethernet Interface: No | 5. Ethernet Interface: No | 5. Ethernet Interface: Yes(Optiion) | 5. Ethernet Interface: Yes | 5. Ethernet Interface: Yes | 5. Ethernet Interface: Yes | 5. Ethernet Interface: Yes(Option) | |
6.
Alarm
Level:02 @ Detector |
6.
Alarm
Level:02 @ Detector |
6.
Alarm
Level:01 @ Detector |
6.
Alarm
Level:01 @ Detector |
6.
Alarm
Level:02 @ Detector |
6.
Alarm
Level:03 @ Detector |
6.
Alarm
Level:03 @ Detector | |
7.
Relay:
02 Relay @ Detector |
7.
Relay:
02 Relay @ Detector |
7.
Relay:
04 Relay @ Detector |
7.
Relay:
04 Relay @ Detector |
7.
Relay:
06 Relay @ Detector |
7.
Relay:
08 Relay @ Detector |
7.
Relay:
08 Relay @ Detector | |
8. Optional more relays can be added | 8. Optional more relays can be added | 8. Optional 2nd Detector for Cross Zone. PreAlarm Option | 8. Optional 2nd Detector for Cross Zone. PreAlarm Option | 8. Optional 2nd Detector for Cross Zone. PreAlarm Option | 8. Optional 2nd Detector for Cross Zone. PreAlarm Option | 8. Optional 2nd Detector for Cross Zone. PreAlarm Option | |
9. Oper Temp: -20 to 60Deg | 9. Oper Temp: -20 to 60Deg | 9. Oper Temp: -20 to 60Deg | 9. Oper Temp: -20 to 60Deg | 9. Oper Temp: -20 to 60Deg | 9. Oper Temp: -20 to 60Deg | 9. Oper Temp: -20 to 60Deg | |
10. Silent Model:No | 10. Silent Model:No | 10. Silent Model:Yes | 10. Silent Model:Yes | 10. Silent Model:Yes | 10. Silent Model:Yes | 10. Silent Model:Yes | |
11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | |
12. Dimension: 7x14 x 22.2 cm | 12. Dimension: 7x14 x 22.2 cm | 12. Dimension: 11.3x30 x 29.2 cm | 12. Dimension: 11.3x30 x 29.2 cm | 12. Dimension: 11.3x30 x 29.2 cm | 12. Dimension: 11.3x30 x 29.2 cm | 12. Dimension: 11.3x30 x 29.2 cm | |
13. Listing: UL and VDS | 13. Listing: UL and VDS | 13. Listing: UL and FM | 13. Listing: UL and FM | 13. Listing: UL and FM | 13. Listing: UL and FM | 13. Listing: UL and FM | |
14. Optional Bar Graph Smk display |
14. Optional 5 rm display |
14. Optional Bar Graph Smk Display | |||||
Spec
BIMDwg |
Spec BIMDwg | Spec BIMDwg | Spec BIMDwg | Spec BIMDwg | Spec BIMDwg | Spec BIMDwg | |
|
|||||||
Due to aesthetic looks |
Small Server room |
Data Center |
Clean Room |
Auditorium |
LIbrary | ||
B. ProSens for
Cold Storage - Standalone, with Net or Net with Sensor Variant. | |||||||
ProSens
Standalone |
ProSens
Net 1TP3U |
ProSens
Net TP4U |
ProSensNet
TP5U |
TopSens
Net |
|||
Application: ASD, EWD, VEWD Programmable. |
Application: ASD, EWD, VEWD Programmable. | Application: ASD, EWD, VEWD Programmable. | Application: ASD, EWD, VEWD Programmable. | Application: ASD, EWD, VEWD Programmable. | MicroSens Color |
MicroSens Dry Contacts | |
Special
Application: Cold Storage. |
Special Application: Cold Storage. | Special Application: Cold Storage. | Special Application: Cold Storage. | Special Application: Cold Storage. | |||
1. Detector Module :02 set. | 1. Detector Module :02 set. | 1. Detector Module :02 set. | 1. Detector Module :02 set. | 1. Detector Module :02 set. | |||
2. Coverage: 3K sqm @ Detector | 2.
Coverage: 3K sqm @ Detector |
2.
Coverage: 3Ksqm @ Detector |
2.
Coverage: 3K sqm @ Detector |
2.
Coverage: 3K sqm @ Detector | |||
3. Max Pipelength: : 300m | 3. Max Pipelength: : 40-50m | 3. Max Pipelength: : 300m | 3. Max Pipelength: : 300m | 3. Max Pipelength: : 300m | |||
4. Max : 63 Holes | 4. Max : 63 Holes | 4. Max : 63 Holes | 4. Max : 63 Holes | 4. Max : 63 Holes | |||
5. Ethernet Interface: No | 5. Ethernet Interface: Yes | 5. Ethernet Interface: Yes | 5. Ethernet Interface: Yes | 5. Ethernet Interface: Yes | |||
6.
Alarm
Level:01 @ Detector |
6.
Alarm
Level:01 @ Detector |
6.
Alarm
Level:02 @ Detector |
6.
Alarm
Level:03 @ Detector |
6.
Alarm
Level:03 @ Detector | |||
7.
Relay:
02 Relay @ Detector |
7.
Relay:
02 Relay @ Detector |
7.
Relay:
06 Relay @ Detector |
7.
Relay:
08 Relay @ Detector |
7.
Relay:
08 Relay @ Detector | |||
8. Optional more relays can be added | 8. Optional more relays can be added | 8. Optional 2nd Detector for Cross Zone. PreAlarm Option | 8. Optional 2nd Detector for Cross Zone. PreAlarm Option | 8. Optional 2nd Detector for Cross Zone. PreAlarm Option | |||
9. Oper Temp: -40 to 60Deg | 9. Oper Temp: -40 to 60Deg | 9. Oper Temp: -40 to 60Deg | 9. Oper Temp: -40 to 60Deg | 9. Oper Temp: -20 to 60Deg | |||
10. Silent Model:No | 10. Silent Model:No | 10. Silent Model:Yes | 10. Silent Model:Yes | 10. Silent Model:Yes | |||
11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | 11. Cold Storage Sensor: Yes | |||
12. Dimension: 7x14 x 22.2 cm | 12. Dimension: 7x14 x 22.2 cm | 12. Dimension: 11.3x30 x 29.2 cm | 12. Dimension: 11.3x30 x 29.2 cm | 12. Dimension: 11.3x30 x 29.2 cm | |||
13.
Listing: UL
and FM |
13. Listing: UL and FM | 13. Listing: UL and FM | 13. Listing: UL and FM | 13. Listing: UL and FM | |||
14. Optional Bar Graph Smk Display | |||||||
Spec BIMDwg | Spec BIMDwg | Spec BIMDwg | Spec BIMDwg | Spec BIMDwg | ProSens & Prosens Net |
ProSens Dry Contacts |
|
Freezer Type Environment where others cannot work |
HIgh Bay Warehouse |
Rubbish Dump Area |
Elevator Shafts |
WinGuard Remote Web Server |
Interface Network Card | ||
C Project Planning Software , Filter, Piping Accessories | |||||||
ASD - Filters Types |
ASD Filter Option and Exproof |
Piping Accessories |
Pipe Reduction Accessories |
Ceiling Drop Accessories | Cleaning Accessories |
Power Supply & Battery | |
D Network Connection Tools - Must have Network Card on Wagner ASD | |||||||
Lan Xpress Software(Free) Manual for Lan Xpress |
Retrieving Selected Performance data(Free) |
Event View Software(Free) |
Data Viewer Software(Free) |
Hard Wired Control and monitoring Technial Manual |
Web Server WinGuard Manual |
||
For Initial Setup of Network Card |
For Maintenance and Operation Purpose |
For Maintenance and Operation Purpose | For Maintenance and Operation Purpose | For Relay Dry contacts Output Interface and Provide Inputs from Wagner ASD to Other Equipment. |
Connection to Network of all ASD with Network Card |
||
Setting IP Addr Individually on Network Card of the Wagner ASD | To retrieve database for purpose of Event or Data Viewer Analysis. 1. Connect PC to Running Wagner ASD Network port(RJ45). 2. Use the Preset IP Address to run the in built software to retrieve your selected date data from Wagner ASD. 3. Save to harddisk of PC. |
Offline Interface with Saved Database file on maintenance PC. Purpose is to view all the Events e.g. 1,Alarm Events. 2. Fault Events. 3. States Event. 4. Info Event. With or Without Color demarcation. |
Offline Interface with Saved Database file on maintenance PC. Purpose is to view the graph chart of Detector 1, Detector 2 for 1. Fire Alarms. 2. Action Alarms 3. Alert Alarms. |
1. Provide 01 Input Reset for Wagner ASD. 2. Provide Relay dry contacts for the below States: a. Alert: 33% Smoke Level. (Fire 1) b. Action: 60% Smoke Level. (Fire 2) c. Alarm: 100% Smoke Level (Fire 3) Different Model of Detection unit Provide from 1, 2 or 3 Level of Alarms. |
Further Details to be confirm
base on case to case basis and this is a high level integration web
server and basic starts from 3K points with Clients available. Exact limit of Wagner ASD connectable to be advise on Case to case basis. |
||
|
|
|
| ||||
Guide on how to Design ASD System using Case Study | |||||||
Sample Data Center Top View |
Sample Data Center Side View |
Smoke Detection Placement Top View |
Smoke Detection Placement Side View |
ASD Piping Layout for Early Smoke Alarm |
Suppression Panel Designer base on Equipment input |
ASD Xpress Design Output |
|
ASD Piping and Accessories BOM from Xpress Plus |
Combine ASD and Detection with Suppression Controls |
BOM for Suppression Controls |
Video Explaining Process |
Detection Placement Excel |
Wagner ASD Project Planner |
Simplex Suppression Designer |
|
Click
Here to
Feedback for
Improvement
. |